\item Pulse 0 to 5 Volts \item Pulse 0 to 5 Volts
\item Frequency 1 kHz \item Frequency 1 kHz
\item Pulse width 12 ns, edge time 5 ns \item Pulse width 12 ns, edge time 5 ns
\item Output impedance 50 Ohm \item Output impedance 50 $\Omega$
\end{itemize} \end{itemize}
\end{itemize} \end{itemize}
@ -69,19 +69,31 @@
\begin{itemize} \begin{itemize}
\item Using default settings \item Using default settings
\end{itemize} \end{itemize}
\item Multiple 1 meter BNC cables with a characteristic impedance of 50 Ohm \item Multiple 1 meter BNC cables with a characteristic impedance of 50 $\Omega$
\begin{itemize} \begin{itemize}
\item One for trigger output, three for the experiment itself \item One for trigger output, three for the experiment itself
\end{itemize} \end{itemize}
\item BNC cable of unknown length with a characteristic impedance of 75 Ohm \item BNC cable of unknown length with a characteristic impedance of 75 $\Omega$
\item 50 Ohm terminator \item Various BNC accessories
\item Various BNC connectors
\begin{itemize} \begin{itemize}
\item Short circuit terminator
\item 50 $\Omega$ terminator
\item T-connectors \item T-connectors
\item Male to male connectors \item Male to male connectors
\end{itemize} \end{itemize}
\end{itemize} \end{itemize}
\subsection{Measurements to be taken}
The following scenarios will be tested:
\begin{itemize}
\item Open termination
\item Short termination
\item Matched termination
\end{itemize}
For each scenario, the full dataset of the oscilloscope will be saved to CSV and analysed at a later moment using Python.
\newpage
\subsection{Setup} \subsection{Setup}
All measurements will be taken using the setup in Figure \ref*{fig:setup}. All measurements will be taken using the setup in Figure \ref*{fig:setup}.
\begin{figure}[H] \begin{figure}[H]
@ -92,15 +104,6 @@
In initial tests, it was found that using a single BNC cable between the terminator and the function generator would produce a reflection, however it would overlap with the original signal, making it difficult to take any measurements. Therefore the setup was built using three cables instead of one in order to delay the reflection to a point where it can be measured. The cables were connected using BNC male to male connectors, making the total cable length about 3 meters. In initial tests, it was found that using a single BNC cable between the terminator and the function generator would produce a reflection, however it would overlap with the original signal, making it difficult to take any measurements. Therefore the setup was built using three cables instead of one in order to delay the reflection to a point where it can be measured. The cables were connected using BNC male to male connectors, making the total cable length about 3 meters.
\subsection{Measurements to be taken}
The following scenarios will be tested:
\begin{itemize}
\item Open termination
\item Short termination
\item Matched termination
\end{itemize}
For each scenario, the full dataset of the oscilloscope will be saved to CSV and analysed at a later moment using Python.
\section{Expected results} \section{Expected results}
We expect the following results for the different termination methods: We expect the following results for the different termination methods:
\begin{description} \begin{description}